Thursday, 13 February 2014
COMPLEX REVISION HIP SURGERY IN A 73 YR OLD WITH FAILED HIP SURGERY (done elsewhere) ,Bangalore , INDIA
73 YR old female , operated elsewhere with a failed hip fracture surgery came to us , with this
preop CRP -
TC -WNL
we planned a revision -calcar replacement stem(intraop gram stain negative for bacteria)
cables and wiring (charnleys ) for trochanter
wiring of trochanter
calcar replacement long stem- in place with wires
bipolar head introduced
prosthesis reduced
wiring of trochanter done with cable(CHARNLEY)
post op x ray
Saturday, 4 January 2014
Complex total hip replacement surgery in a patient with protrusio acetabuli (rheumatoid arthritis) ,- bangalore , india
65 yr old , rheumatoid arthritis lady came to us on a wheel chair, not able to walk -
she had a history of RA , on steroids , osteoporotic bone and diabetic
pre op plan -
correct shortening of 2 cms
lateralize hip center
build up base of acetabulum with mashed morcelized bone graft
use oversized cup to get a peripheral fit with screws
v. off set 54 mm and h offset 50 mm
we used pinnacle uncemented cup - 180 degree coverage
cup insitu fixed with two screws
she had a history of RA , on steroids , osteoporotic bone and diabetic
pre op plan -
correct shortening of 2 cms
lateralize hip center
build up base of acetabulum with mashed morcelized bone graft
use oversized cup to get a peripheral fit with screws
v. off set 54 mm and h offset 50 mm
we used pinnacle uncemented cup - 180 degree coverage
cup insitu fixed with two screws
neutral liner UHMWHDP
LINER INSITU
SUMMIT UNCEMENTED STEM
COCR -32 HEAD
COCR HEAD INSITU
HEAD MATED TO SUMMIT STEM
AIMS ACHIEVED-
shortening 2 cms - gained
cup lateralized
cup 50 peripheral fit and offset targets achieved intraop
in addition - iliopsoas , adductor and it band released